Detailed Product DescriptionSulfur Measurement Range:0.0017% ~ 5%; 1%-80% (two Options)Measurem
WhatsApp +86 13816217984
Email:info@qinsun-lab.com
Sulfur Measurement Range: | 0.0017% ~ 5%; 1%-80% (two Options) | Measurement Time: | 60-180 Seconds |
---|---|---|---|
Single Sample Automatic Measurement, Measurement Repetition Times: | 1. 2. 3. 5. 10 Arbitrary Setting, The End Of The Measurement To Give The Average And Standard Deviation | Repeatability (r): | < 0.4347 X0.6446 (X= The Average Of Two Repeated Test Results) |
Reproducibility (R): | < 1.9182 X0.6446 (X= The Average Of Two Single, Independent Test Results) | Sample Size: | 5ml ~ 6ml |
Storage: | Can Store 10 Calibration Curves | Working Conditions: | Temperature :10 ~ 30℃; Relative Humidity :≤85% (30℃) |
Power Supply: | AC100-220V/50Hz; Rated Power :50W | Size And Weight: | 460mm*260mm*260mm; 11kg |
Highlight: | ASTM D 4294 Oil Testing Equipment X-ray fluorescence sulfur analyzer ASTM D 4294 sulfur analyzer |
Energy dispersive X-ray fluorescence sulfur analyzer is a special analyzer based on energy dispersive X-ray fluorescence spectroscopy. The analyzer principle, design structure, instrument elements, analytical method operation flow, error and reproducibility all conform to GB/T 17040-2019 and ASTM D4294 for the determination of sulfur content in petroleum and petroleum products.
◆ Measuring sulfur content of crude oil, petroleum, heavy oil, diesel oil, kerosene, naphtha;
◆ Measuring the total sulfur content of coal chemical products, such as primary benzene;
◆ Measurement of sulfur content in other liquid or solid fine powder samples such as petroleum coke.
◆ Intelligent electromechanical integrated microcomputer design,8 inch wide viewing Angle capacitive touch screen (1024*768) display
◆ Wide detection variety, wide detection range, fast analysis speed, less standard sample consumption;
◆ The instrument has automatic peak stabilization function and automatic diagnosis function, monitoring the working state and electrical parameters of the instrument;
◆ Disposable Mylar film sample cup to avoid cross contamination; Sample cup production is convenient and fast;
◆ Accurate positioning of the sample table, easy to place the sample and replace the anti-oil leakage film, and avoid the possibility of contamination of the detection system;
◆ Large storage capacity of instrument data, 4096 content analysis results and 8192 count measurement data, 16 instrument calibration results.
◆ Thermal printer automatically prints test results;
◆ The instrument automatically selects the working curve without user intervention;
◆ The user can choose the measurement result unit, ppm or (m/m)%;
◆ Safe radiation protection measures, no harm to individuals and groups of ionizing radiation.
1. Sulfur measurement range: 0.0017% ~ 5%; 1%-80% (two options)
2. Measurement time: 60-180 seconds;
3. Single sample automatic measurement, measurement repetition times: 1. 2. 3. 5. 10 arbitrary setting, the end of the measurement to give the average and standard deviation;
4. Repeatability (r): < 0.4347 X0.6446 (X= the average of two repeated test results);
5. Reproducibility (R): < 1.9182 X0.6446 (X= the average of two single, independent test results);
6. Sample size :5ml ~ 6ml;
7. The instrument can store 10 calibration curves;
8. Working conditions: Temperature :10 ~ 30℃; Relative humidity :≤85% (30℃); Power supply :AC100-220V/50Hz; Rated power :50W;
9. Size and weight: 460mm*260mm*260mm; 11kg.
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.