Applicable standards:GB/T5464-2010 GB/T8624ISO1182 Fire reaction test for building products -- non-c
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Applicable standards:
GB/T5464-2010 GB/T8624ISO1182 Fire reaction test for building products -- non-combustible test
Scope of application:
ZNJCB-2 building materials incombustible test furnace according to the national standard
Developed according to the technical indicators and requirements specified in GB/ T5644-2010, and applicable to the test method for evaluating the combustion performance of building materials under laboratory conditions. It is suitable for testing the combustion performance classification of Grade A fireproof materials in the combustion performance classification of building materials GB8624.
Technical parameters:
1. The inner diameter of the furnace tube of the heating furnace is 75mm+1mm, the outer diameter is 90mm±1mm, the height is 150mmt1mm, and the power is about 2KW
2, install the thermocouple in the furnace, sample center thermocouple, sample surface thermocouple,
3. Thermocouple scanning device that can be rotated and lifted 360 degrees
4, stainless steel inverted cone air flow stabilizer and cylinder fairing,
5, the software automatically controls the heating rate, and controls the furnace temperature in stages.
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.