Overview
1.1 Applicable for testing thermal protection performance of single-layer or multi-layer materials used in protective clothing exposed to convective and radiant heat hazards. Not suitable for non-flammable materials or those prone to melting/dripping at high temperatures.
1.2 Design principle:
a. Horizontal placement of flame-retardant samples under combined convective/radiant heat sources
b. Exposure time recorded when transmitted heat equals second-degree burn threshold
c. Direct contact simulation (0mm gap) vs spaced contact (6.5mm gap)
d. Thermal protection value (TPP) calculation: Intersection of heat flux-time curve with Stoll curve
e. Stoll curve: Standard curve relating burn time to energy exposure – values above curve indicate risk of second-degree burns
Compliance Standards
GB 8965.1-2009 Appendix A, GA 10-2014 Appendix A, NFPA 1971-2017, ISO 12749, GB/T 38302-2019
Product Advantages
1. Computerized control system with LabVIEW software integration
a. User-friendly interface with automated calculations
b. Real-time data acquisition (20 samples/sec) and Stoll curve intersection detection
c. Intelligent temperature compensation algorithm
2. Automated thermal shield system:
a. ≤0.5s response time for heat shield retraction
b. Water-cooled shielding mechanism
3. Precision ignition system:
a. High-voltage spark generator with safety interlock
b. 38mm diameter gas burner with adjustable air/fuel mixture
4. TPP automatic calculation:
a. Integration of exposure time and total heat flux
b. Digital display of calculated TPP value
Technical Specifications
Specification | Details |
---|---|
4.1 Heat sources | 4.1.1 Radiant: 9×T-150 quartz lamps (10–50 kW/cm² @ 127mm) 4.1.2 Convective: Twin gas burners (45° angle, 10–50 kW/cm² each) 4.1.3 Total heat flux: 83±2 kW/cm² |
4.2 Sensors | Copper calorimeter probe (Φ25mm) with ±0.1℃ resolution Stoll curve intersection detection system |
4.3 Data acquisition | 20 Hz sampling rate prior to 250℃ Automatic TPP calculation via software integration |
4.4 Safety features | High-voltage interlock system Water-cooled shield mechanism Emergency shutdown protocol |
4.5 Dimensions | Main chamber: 800×500×550mm Instrument footprint: 1200×800×1000mm |
4.6 Power requirements | AC 220V±10% 50Hz, 3kW maximum |
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.