Main PurposeIt is mainly used for the extremely high - temperature pre - treatment of safety helmets
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Main Purpose
It is mainly used for the extremely high - temperature pre - treatment of safety helmets.
Compliance Standard
GB/T2812-2019
Technical Parameters
1. Test chamber temperature: Room temperature - 200°C, with the standard operating temperature being 150±5°C. 2. Test time: 0 - 99 minutes, adjustable, with the standard being 60±2 minutes. 3. Number of test samples: 1 - 4 helmets. 4. Head mold temperature: 50°C±2°C. 5. Test head mold: Wall thickness > 1.5mm, size according to No.1 in GB2812, made of aluminum alloy with a hollow interior. 6. Temperature - measuring point of the head mold: The distance from the mid - point of the head mold is < 40mm. 7. Instrument dimensions: 870*710*1100mm
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.