Advanced Capillary Flow Porometers yield very objective, accurate and reproducible results, consider
WhatsApp: +86 13816217984
Email: info@qinsun-lab.com
Advanced Capillary Flow Porometers yield very objective, accurate and reproducible results, considerably reduce test duration, and require minimal operator involvement. Advanced Porometers are fully automated and are designed for Linear turbulence-free test gas flow. The pressure is measured close to the sample and therefore, the correction term in the differential pressure measurement is minimized. Required amount of pressure is uniformly applied on the O-ring seals on the sample and the need for hand tightening the cap on the sample chamber to apply pressure on the O-ring is eliminated. Automatic addition of wetting liquid reduces test time appreciably. This sophisticated instrument has found applications in a wide variety of industries.
Operation Principle
A wetting liquid is allowed to spontaneously fill the pores in the sample and a nonreacting gas is allowed to displace liquid from the pores. The gas pressure and flow rates through wet and dry samples are accurately measured. The gas pressure required to remove liquid from the pores and cause gas to flow is given by
D = 4 g cos q / p
where D is the pore diameter, g is the surface tension of liquid, q is the contact angle of liquid, and p is the differential gas pressure. From measured gas pressure and flow rates, the pore throat diameters, pore size distribution, and gas permeability are calculated.
ứng dụng
The Capillary Flow Porometer is used for R&D and quality control in industries worldwide such as filtration, nonwovens, pharmaceutical, biotechnology, healthcare, household, food, hygienic products, fuel cell, water purification, and battery. Samples often tested include filter media, membranes paper, powders, ceramics, battery separators and health care products.
Technical Parameters
Items | Parameters |
Pore size range | 0.013-500μm |
Permeability range | 1 x 10-10, 1 x 10-6 (microflow at cc/sec/m/torr) |
Sample size | 0.5" - 2.5"diameter |
Pressure range | 0-500psi |
Pressurized gas | Clean, dry, compressed air or non-flammable, non-corrosive gases |
Pressure transducer range | 0-500psi |
Resolution | 1/60000 |
Accuracy | 0.15% of reading |
Mass flow transducer range | 10 cc/minute - 500 L/minute |
Power requirement | 110/220 VAC, 50/60 Hz (Other power sources can be used ) |
Dimension | 30" H x 19" W x 18.5" D |
Weight | 100Ibs |
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.