Detailed product descriptionSTD:Automatic Distillation ApparatusStandard:ASTM D86Temperature Ra
WhatsApp +86 13816217984
Email:info@qinsun-lab.com
STD: | Automatic Distillation Apparatus | Standard: | ASTM D86 |
---|---|---|---|
Temperature Range: | Environment Temperature~400°C | Temperature Sensor: | RTD Pt100 |
Distillation Rate: | 4~5ml/min | Cooling System: | Compressor Refrigeration |
Condenser Temperature: | 0~60℃ | Recovery Room Temperature: | 10~40℃ |
Highlight: | oil analysis machineoil testing equipment |
Automatic petroleum products distillation tester conforms to standard ASTM D86.
which is suitable for testing distillation characteristics of natural gasoline (stable light hydrocarbon), motorgasoline, aviation gasoline, jet fuel, special boiling point solvent, naphtha, kerosene, diesel, gas oil distillate fuel and similar petroleum products.
ASTM D86 Petroleum Products Laboratory Automatic Distillation Apparatus:
1. Instrumentation tests the whole process automatically by the industrial computer, full touch 10.4-inch LCD test, the whole process shows data and correlation curves of the temperature and volume.
2. Liquid level tracking system consists of high subdivision step US Haydon brand linear motor and imported photoelectric tracker (Japan KEYENCE).
3. Cooling medium inner loop, the first domestic use antifreeze instead of cooling water.
4. Can automatically control the distillation heating circuit, and makes the sample flow rate control from the initial distillation point to 95% within 4 ~ 5 ml per minute.
5. Can provide initial distillation point temperature and final distillation point temperature value, also can provide temperature and flow rate at percent point.
6.Can detect local atmospheric pressure automatically and correct for the temperature at standard atmospheric pressure automatically.
7. User can choose to crease the test according to the steam temperature or volume recovered.
8. Can store, query and print test results.
9.Initial boiling point temperature is detected by the optical fiber sensor.
10.With a fire extinguishing system.
11.It comes with a safe temperature setting function.
12.The instrument can automatically detect and display temperature and velocity time for every 5% volume point.
Power | AC220V±10% 50HZ |
Temperature Range | Environment temperature~400°C |
Temperature Control Precision | 0.1℃ |
Temperature Sensor | RTD Pt100 |
Start Heating To Initial Distillation Point Time | 5~15min |
Distillation Rate | 4~5ml/min |
Residues In Flask is 5 ml | less than 5 min |
Recycling Volume Measurement Range | 0~100ml |
Recycling Volume Measurement Precision | ±0.1ml |
Cooling System | Compressor Refrigeration |
Condenser Temperature | 0~60℃ |
Recovery Room Temperature | 10~40℃ |
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.