DescriptionThe STD-RCF 6 machine is designed to run the standard three ball on rod rolling contact
WhatsApp +86 13816217984
Email:info@qinsun-lab.com
The STD-RCF 6 machine is designed to run the standard three ball on rod rolling contact fatigue test geometry, in which three balls, separated by a retainer, are loaded against a rotating rod specimen, by applying an axial force across two taper bearing cups, mounted above and below the three balls.
Test Geometry: | Ball on rod |
Rod Diameter: | 9.53 mm and 10 mm |
Ball Diameter: | 12.7 mm |
Motion: | Rotary |
Contact Load: | 200 to 1200 N |
Fatigue Cycles per Revolution: | 2.3828 with 9.53 mm diameter rod |
2.3654 with 10 mm diameter rod | |
Speed: | 300 to 15.000 rpm |
Motor: | 1.4 kW @ 15.000 rpm |
Temperature: | Ambient to 80°C |
Test Stations: | Up to 6 |
Control: | PLC |
Lubricant Service Module: | Included |
Manually Controlled Parameters | |
Load: | Pneumatic – actuators in parallel |
Rotational Speed: | Each test station independently controlled |
Temperature: | Each test station independently controlled |
Vibration Level: | Each test station |
Data Logged Parameters | |
Load: | Pressure transducer – one per installation |
Temperature: | Yes – each test station |
Test Duration: | Yes – each test station |
Services | |
Electricity per Test Station: | 220/240V, single phase, 50 Hz, 4.5 kW |
110/120V, single phase, 60 Hz, 4.5 kW | |
Clean, dry air: | 4 cfm at 8 bar (120 psi) |
Từ chối trách nhiệm: Nội dung trên chỉ dành cho tham khảo và giao tiếp giữa những người trong ngành và không đảm bảo tính chính xác hoặc đầy đủ của nó. Theo luật pháp và quy định có liên quan và các quy định của trang web này, các đơn vị hoặc cá nhân mua các mặt hàng liên quan phải có trình độ và điều kiện trình độ hợp lệ.
Điện thoại công ty
+86-21-6420 0566
Thời gian làm việc
Thứ Hai đến Thứ Sáu
Điện thoại di động:
13816217984
Email:
info@qinsun-lab.com